Permit: T02EL00359

Parcel: 127110850


Addresses:

5970 E 2ND ST #02


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T02EL00359

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/22/2002 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*OK CABLE DROP OK TO CLEAR TEMP SERVICE.
03/19/2002 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0245*OK TO CLEAR CABLE DROP ONLY NOTES 1.) INSTALL ROMEX CONNECTOR ON EX FAN. 2.) REPLACE 2 OR MORE GANG BOXES THAT HAVE ROMEX CLAMPS BROKEN OFF. ROMEX TO BE SECURED TO BOX WITH EXCEPTION FOR SINGLE GANG BOXES ONLY 370-17 N.E.C.