Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T02EL00298
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2002 | ELECTRIC - FINAL | Approved | ||
02/13/2002 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*1.) PLEASE VERIFY WATER AN GAS BONDING CAN NOT LOCATE 2) PLEASE VERIFY GROUND RODS CAN NOT LOCATE. 3.) MAIN BREAKER IS TO HAVE A HOLD DOWN CLIP/SCREW. 384-16. 4.) ROOF CLEARANCE IS TO BE MAINTAINED ACCROSS ROOF TO THE SOUTH 230-24. 5.) PLEASE INSTALL A WEATHER PROOF COVER ON THE RECEPTACLE ON THE NORTH SIDE OF THE HOUSE |