Permit: T02EL00282

Parcel: 126090700


Addresses:

116 N REGENCY PL

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
03/04/2002 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection 0000*OK TO CLEAR/OK CABLE DROP.
02/25/2002 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245*SEE ITEM #3 LAST INSP.
02/20/2002 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0245*NOTES 1.) PERMANENT ADDRESS LABEL REQUIRED MUST BE SCREWED OR RIVITED TO ENCLOSURE PER 230-70 N.E.C. #9287 CITY ORDIN. 2.) GAS & WATER PIPING MUST BE BONDED 250-104 NEC. 3.) USE 1/4 MIN ANCHOR BOLTS TO SECURE RISER TO STRUCTURE, NOT SHEET METAL SIDING. 110-12 N.E.C. 4.) I.D. CIRCUIT BREAKERS.