Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/26/2002 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 02/06/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) IMPROPER WIRING METHODS TO EXHAUST HOOD SINGLE OPEN CONDUCTOR UNPORTECTED ETC. 2.) REVERSED ON RECEPTACLER. USING 3 WIRE GROUNDING RECEPTACLES ON A 2 WIRE UNGROUNDED SYSTEM. 3.) SUBPANEL (OLD SERVICE) NEEDS TO BE REPLACED IMPROPER WIRING METHODS OPEN CONDUCTORS ILLEGAL TAPS, SPLICER, USING WATER LINE AS CONDUIT, CONDUIT ON ROOF WRONG, SEPARATED, L.B. IMPROPERLY INSTALLED. 4.) A SMOKE DETECTOR IS REQUIRED FOR EACH BEDROOM INSTALL PER MANUFACTURER RECOMMENDATION. 5.) COOLER IMPROPERLY SUPPORTED ON MASONARY BLOCKS DUCTING IS ROTTED ETC. |