Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - RECONNECT
Permit Number - T02EL00223
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/22/2002 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*1.) THE 125A PANEL OUTSIDE IS NOT APPROVED TO HAVE THE TRAILER RECEPTACLE INSTALLED INSIDE OF IT IT MUST BE INSTALLED IN ITS OWN OUTLET BOX. 2.) SEAL THE ONE INCH HOLE BEHIND TH EBOX 3.) THE LAST INSPECTOR REQUESTED THAT THE ROMEX BELOW THE WINDOW OUTSIDE PORTCH AREA BE PROTECTED IT CANNOT BE RUN OUT IN THE OPEN. 4.) THE SHED WIRING IS UNAPPROVED ALL WIRING HAS TO BE PROTECTED 5.) THE NEUTRALS IN THE INSIDE PANEL NOT TERMINATED IN PANEL 6.) PROTECT ALL WIRING IN CLOSETS. 7.) INSTALL SMOKE DETECTORS IN BEDROOM. 8.) OBTAIN AN ELECTRICAL C-11 CONTRACTOR TO MAKE CORRECTIONS AND CHECK ALL OTHER ELECTRICAL. | |
02/01/2002 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection 0000* |