Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/02/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS HAVE BEEN MADE |
| 06/01/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999* 1) ONLY ONE SLIP NUT ALLOWED ON THE OUTLET SIDE OF THE TRAP. 2) CAULK SINK 3) PLAN REQUIES RIGID CHROME PLATED GRASS SUPPLY TABING |