Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05943
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/17/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PROVIDE 1" CLEARANCE AROUND WATER HEATER FLU AND 2ND FLOOR CHASE 2) FIRE BLOCKS MISSING AT MECHANICAL STAND 3) PROVIDE ENGINEERING FOR FLOOR TRUSS OVERNOTCHED TOP AND BOTTOM CHROD (FL1) AT KITCHEN 4) OK TO INSULATE LEAVE TRUSS AREA OPEN FOR RE-INSPECTION | |
04/16/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NAIL PROTECT COPPER LINE IN GARAGE WITHIN 1 1/2 FROM EDGE OF STUD 2) WATER LINES CANNOT BE WITHIN 12" OF RECESS LIGHTS 3) FIREBLOCK MISSING AT STAIRS FIRST LANDING 4) DWV'S NOT HOLDING TEST 2ND FLOOR 5) PROVIDE 1" CLEARANCE FOR WATER HEATER FLU PIPE AT 2ND FLOOR CHASE FROM COMBUSTIBLES 6) C2 TRUSS 2ND FLOOR IS WARPED CHECK YOUR FLAT BLOCKING 7) FIREBLOCK MECH PLENIUM 8) COMPLY WITH DETAILS 49 AND 50 PG AD3 |