Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM05940

Parcel: 137314290

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/30/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/29/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) GARAGE SHEARWALL 3 MUST BE ATTACHED TO BOTTOM CHORD OF TRUSS PER 10/DT1 PRESENTLY ATTACHED TO TRUSS DEADWOOD. PROVIDE CITY APPROVED ENGINEER DETAIL OF PROPER CONNECTION OR SHEAR PER PLAN 2) OK TO DRY IN