Permit: T02CM05906

Parcel: 110033800

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM05906

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/09/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/21/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) H.D. NOT DONE-OK TO LATH
04/17/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) HOLDOWN NORTH EAST SIDE OF HOUSE WILL NEED EPOXY SPECIAL INSPECTION 2) NAIL SHEAR WALL TO DOUBLE STUDS AT HOLDOWN EAST WALL 3) STRAP NOT NAILED TO 2ND FLOOR WALL NORTH SIDE OF HOUSE
04/14/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) INSTALL ALTERNATE HD'S AT MISSES-(PER SCHEDULE SHEET S-1) 2) TRUSS BLOCKING NOT NAILED PER DETAIL 1/SD3 3) GABLE END BRACING NOT PER DETAIL 7/SD3 4) PROVIDE ACCESS TO ROOF