Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/10/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/06/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) MANY SHEARWALLS MISSED-#3 REQUIRED FOR ELEVATION D (SEE SHEARWALL PLAN) 2) TIGHTEN ALL RED-HEADS 3) SHEAR TRANSFER NOT PER DETAIL 3/D3 4) ROOF NAILING OK TO COVER |
| 03/04/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |