Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05860
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/18/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/17/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) INSTALL BANG PLATE ELECTRIC UNDER KITCHEN WINDOW 2) ALL HOLES IN FHA STRAPS MUST BE NAILED | |
03/14/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAPS AT GAS MAIN SHOULD BE NAILED NOT SCREWED-AND AT HOME RUNS 2) PROTECT WIRING AT NORTH EAST GARAGE TOP PLATES A AND BELOW KITCHEN WINDOW 3) PROTECT PEX AT SOUTH LAUNDRY TOP PLATES 4) COMPLETE THE FIRE BLOCKING AT 2ND FLOOR NORTHWEST WINDOWS |