Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM05832

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/04/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) NEED EXPLANATION FOR TIMBER LINE HEADER INFO 2) NEED A.35 AT 2 X 8 LEDGER, WILL CHECK AT NEXT INSPECTION
01/31/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) EXTERIOR SHEAR WALLS, NEED DETAILS FOR SHEAR TRANSFER ARE TRUSSES, STRUCTUAL STRUTS ? 2) ROOF NAIL 10D 6-12 ON CENTER USED STAPLES 3) NEED TIMBER LINE CONVERSION FOR HEADERS, FOR THIS SUB DIVISION 4) GABLE END BRACES 8'-0" ON CENTER USE NAILS IN SHEAR 5) LATERAL BRACE AT ALL TRUSS 6) WALKED ROOF ALL NAILING COMPLETED 7) GABLE END DETAILS SHOWIGN A.35 12" ON CENTER OK FOR SHEAR TRANSFER IF TRUSS IS A S/STRUCT 8) NEED WIND BRACE AT NORTH/EAST CORNER 9) NEED USP HANGER BOOK FOR NAIL SIZES-CROSS REF HUS28 SIMPSON USE 16D COMMON NAILS 10) NEED LEDGER TO WALL CARRYING GARAGE TRUSSES DETAIL PUT ON PLAN 11) H-2 TRUSS GARAGE NEED AT LATERAL OR T BRACE