Date Description Inspector Results Comments
02/05/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/04/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) WRONG NAILS USED IN GARAGE HANGERS AT GIRDER 2) ALL INTER. SHEAR WALLS TO BE TRANSFERED PER DETAIL 502/SD 3) INTERIOR BEARING ON WRONG AREA OF TRUSSES 4) MISSED #3 SHEAR WALL AT FRONT ENTRY 5) SHEAR PANELS IN LIVING ROOM NOT SHOWN ON THIS PLAN 6) 36" LONG CS20 STRAP 503/SD 7) NEED TRUSS DRAWINGS 8) INSTALL RAT RUN AT GARAGE DEADWOOD