Permit: T02CM05771

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/29/2003 FRAMING Approved IVRS - Inspection 0000*
01/28/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NEED TRUSS (REPAIR DETAIL) FOR GARAGE. OK TO INSULATE CALL BACK BEFORE COVERING
01/27/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) STAPLES IN PLASTIC PLUMBING FLOOR WALL INTERS ARE SUPPOSED NOT TO BE DONE UNTIL LATH IS COMPLETE, CHECK WATER AND VENTS 2) WHEN DRILLING HOLES FOR PLUMBING SPREAD THEM AROUND DON'T CONCENTRATE HOUSE ALL IN ONE AREA 3) BLOCK ALL VENTS 4) GABLE TRUSS NOTCHED FOR OUT RIGGERS, DAMAGED TOP CHORD AT GARAGE 5) MISSING LEFT BEARING PT ABOVE WATER HEATER, FULL 6) SUPPORT KITCHEN SINK DRAIN ARM 7) MISSING H.D. AT GARAGE WALL #5, ALSO RUN OSB FROM BOTTOM OF DROP TO ROOF