Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T02CM05748
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2003 | MECHANICAL - FINAL | Approved | IVRS - Inspection 0000*/ 1) OK FOR C OF O | |
| 06/20/2003 | MECHANICAL - FINAL | Denied | IVRS - Inspection 0999* WATER HEATER VENT STILL NOT FASTENED CORRECTLY. RECALL FOR INSPECTION | |
| 06/19/2003 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection 0000* 1) PROVIDE MIN 3 SCREWS I WATER HEATER VENT CONNECTOR . EXTEND VENT 2' ABOVE PARAPET WALL 2) PAINT ALL EXPOSED PVC W /LATEX PAINT. 3) GAS SHUT OFF VALVE MUST PRECEDE GAS FLEX. 4)OPEN UP DRAIN PORT IN WASHER BOX. |