Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/03/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* R.O. UNIT HAS BEEN REMOVED. PLUMBER TO INSTALL PROPER CO FOR K SINK |
| 07/01/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 06/30/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY ON RO-ALSO PROVIDE ACCESS TO CLEANOUT |
| 06/29/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PLEASE READ NOTE #2-ABOVE. THE DRAIN MAY NOT BE DIRECTLY CONNECTED TO WASTE PIPING BESIDES SLIP NUT EXTENSION TAIL PIECE IS NOT APPROVED IN THE HORIZONTAL POSITION; IT IS NOT A DRAINAGE FITTING |
| 06/25/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ABS MAY NOT BE TAPPED OR THREADED TO MAKE A CONNECTION 2) R.O. DRAIN MAY NOT BE DIRECTLY CONNECTED TO WASTE PIPING. THIS IS CONSIDERED A CROSS CONNECTION |
| 06/24/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999* DOOR LOCKED NO ACCESS |