Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/15/2003 | ELECTRIC - INTERMEDIATE | Approved | ||
| 05/02/2003 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000* SUPPORT CONDUITS ABOVE CONTROL PANEL WITHIN 3' 2.) SUPPORT M/C CABLE WITHIN 12" OK WALLS. |
|
| 04/30/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0920*GATES LOCKED NO ACCESS 2:45PM. | |
| 04/28/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0245*MC CABLE TO BE SUPPORT WITHIN 12" EACH TERMINATION AND AT 6' INTERVALS PER NEC. 2.) INSULATE FROM COPPER WATER LINES. 3.) LETTER FROM ARCH VERIFY USE OF MC CABLE. |
|