Permit: T02CM05731

Parcel: 124080350


Addresses:

1515 E 8TH ST #01

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
03/25/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*CORRECTIONS MADE OK
OK TO COVER WALLS.
03/24/2003 PLUMBING - INTERMEDIATE Denied 1.) HORIZONTAL X HORIZONTAL CHANGE IN DIRECTION SHALL BE THROUGH A WYE BRANCH FITTING OR EQUIVIENT SWEEP.
2.) WHILE PEX PIPING MAY BE BUNDLED, HOT AND COLD MUST BE SEPARATED TO AVOID HEAT TRANSER.
3.) HORIZONTAL SECTIONS OF VENT TO BE SUPPORTED.
4.) DELTA REVISION DELETES GAS FROM PLAN.