Permit: T02CM05717

Parcel: 118122240


Addresses:

244 E 24TH ST


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T02CM05717

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/27/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*
03/11/2004 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection 0000*
02/27/2004 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*
04/02/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*
04/01/2003 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection 0000*
12/13/2002 MECHANICAL - FINAL Denied IVRS - Inspection 0999*/ 1) ROOF ON THIS HOUSE HAS BEEN REPLACED WITHOUT INSPECTION OR APPROVAL. 2 X 4 RAFTERS ARE INSTALLED AT 48" ON CENTER. PROVIDE CITY OF TUCSON APPROVED ROOF PLAN AND MAKE REPAIRS 2) DUCT TRANSITION ON EAST SIDE OF HOUSE ARE NOT INSULATED REQUIRE R-6 MINIMUM 3) DUCT BROKEN, IMPROPER SPLICE AT LIVING ROOM 4) GAS LINE MISSING ROOF JACKS 5) NO ELECTRIC DATA PLATE/LABEL A/C UNIT 6) A/C GROUND NOT PROPERLY COLOR CODED MUST BE GREEN 7) NO CONDENSATE DRAIN OR TRAP ON A/C 8) ELECTRIC JUNCTION BOXES CANNOT BE CONCEALED IN CAVITIES