Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05701
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/12/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/11/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) OK TO INSULATE ALL BUT INTERIOR HOLDOWN BAYS | |
03/10/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) MOVE PEX FROM KITCHEN CAN LIGHTS 2) BANG PLATE STOVE WIRE, AND WIRES NORTH AND SOUTH OF FRIDGE PEX AND TOP PLATES NORTH OF HALL TUB 3) STRAP INTERIOR TOP PLATES WHERE GLU LAM IS BEARING INSIDE ENTRY 4) ADD 2ND KING UNDER SOUTH END OF GLU LAM 5) NEED ALTERNATE HD'S FOR BLOWOUTS 6) BANG PLATE WIRES AT BACKSIDE OF STOVE WIRE AND SOUTEAST CORNER OF MASTER BATH 7) FINISH HOT WATER FLU FIREBLOCKING AT ROOF 8) REMOVE ROOFING FROM FURNACE FLUE | |
03/06/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) MESH NOT DONE FOR INTERMEDIATES |