Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T02CM05700
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/06/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*CORRECTIONS MADE OK 2.) GREASE TRAP INSTALLED PER APPROVED PLAN 3.) ABS DWV UNDERGROUND OK OK TO COVER. |
|
05/05/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*DOOR LOCKED NO ACCESS. | |
05/02/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) GALVANIZED PIPE MAY NOT BE USED FOR WASTE PIPING BELOW THE FLOOR. 2.) SEE ARCHETECTS NOTE A4 PLUMBING PLAN USE JR SMITH #8020 20 GAL RECEPTOR SURFACE MOUNT BELOW SINK. 3.) FLOW CONTROL TO BE INSTALLED IN TAILPIECE 4.) INSTALL PER PLAN. |
|
04/08/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) NOT INSTALLED PER PLAN 2.) EXPOSE ALL NEW PIPING FOR INSPECTION 3.) IT APPEARS THAT A REVISION HAS BEEN PENCILED IN ON THE APPROVED PLAN. THIS WILL REQUIRE A DELTA PLAN REVISION OR SK DRAWING TO BE SUBMITTED AND APPROVED. 4.) ALL NEW PIPING TO BE SHOWN ON THE PLAN INCLUDING POC TO EXISTING PIPING. 5.) PLUMBER PLEASE NOTE THAT THE TRAP AND TRAP ARM ARE TO BE SAME SIZE. 6.) ALL WASTE PIPING TO BE TESTED THRU ROOF. |