Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05677
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/19/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
03/18/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FRAME AROUND PLUMBING IN GARAGE 2) FHA STRAPS ON OVERDRILLED PLATES MUST BE LONG ENOUGH TO SPAN THE OVER DRILLED AREA AND MUST HAVE AT LEAST 3 NAILS IN EACH END 3) PLATES REQUIRE ANCHOR WITHIN 12" OF END CUTS 4) ELECTRIC FEED TO KITCHEN ISLAND NEEDS BETTER PROTECTION AT WALL |