Permit: T02CM05647

Parcel: 14118001C


Addresses:

10222 E RITA RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
06/30/2003 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
05/16/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*TOP OUT MAIN BUILDING.
05/13/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*NORTH WALL TO 18'8" AFF.
05/09/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*TOP SOUTH WALL & RETURN TO KNOCK OUT.
05/08/2003 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000*SEE YESTERDAY'S NOTES.
05/07/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*
05/05/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*16' AFF GRID LINE 3.
04/28/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*GRID LINE 3; 12' AFF.
04/25/2003 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*LAP LENGTH FOR 2 BARS IN 8" MASONRY IS 47" ALL MASONRY WITH 2 BARS IN 1 CELL MUST HAVE 7' BARS SWITCHED FOR 8' BARS.
2.) HAVE SPECIAL INSPECTOR CALL ME WHEN AT ARRIVES @ SITE.
04/17/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*SOUTH EAST WEST 8' AFF
2.) NORTH CALS. 4'8" AFF
04/11/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*1. 4' AFF A3 AROUND TO K-3.
2.) VERTICALS BELONG INSIDE BOTH 135' HOOKS OF TIE SETS.
04/02/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*STEM WALL.