Permit: T02CM05647

Parcel: 14118001C


Addresses:

10222 E RITA RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
07/30/2003 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*
05/09/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*FOOTING FOR HEADWALL @ WEST END.
04/08/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*HEADWALL & EXTENSION OF EXISTING HEADWALL PER E/2.
03/28/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*1.) FIELD REPORTS FROM SPECIAL INSPECTOR REQUIRED TO BE ON SITE.
2.) LINE A & K OK TO POUR AFTER FOOTINGS CRUMBED OUT & CLEARANCES CORRECTED.
03/27/2003 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection 0000*
1.) 3" CLEARANCE NEEDED FOR REBAR TO EARTH
2.) LINE 1 F2 FOOTINGS B-J OK TO POUR WHEN SPECIAL INSP. CONFIRMS PROPER CLEARANCE OF STEEL.
3.) WF3 @ 1K OK TO POUR.
4.) LINE 3 WF1 OK TO POUR AFTER SPEC. INSP. CONFIRMS CLEARANCE AND ALTERNATE BENDS OF VERTICAL STEEL.
5.) OK TO POUR FOOTINGS ON LINE 3 @ B,D,F,H,