Permit: T02CM05645

Parcel: 110100750

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/21/2003 FRAMING Approved IVRS - Inspection 0000*
10/06/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NEED DWV 2) CLARIFY WINDOW ADDITION
10/03/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) TURN 4 GANG BLOCK 90 DEGREE AT FIREPLACE (USE COMPLETE 2 X 4 X 1') 2) BANG PLATE ALL WIRES WITHIN 1 1/4" OF STUD/PLATE FACES-MANY 3) GROUND METAL PANCAKE BOXES 4) NO WATER IN DWV TEST 5) INSTALL DUCT IN LAUDNRY CEILING
10/01/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
09/25/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) MECHANICAL DONE EXCEPT LAUNDRY TO POWDER DUCT 2) ELECTRIC N.R. 3) PLUMBING NEED DWV TEST, GAS PRESSURE TEST, WATER PRESSURE HOT AND COLD 4) FRAME OK EXCEPT NAIL OSB AT HIS CLOSET HEADER
08/13/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
08/11/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*