Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/21/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/06/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) NEED DWV 2) CLARIFY WINDOW ADDITION |
| 10/03/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) TURN 4 GANG BLOCK 90 DEGREE AT FIREPLACE (USE COMPLETE 2 X 4 X 1') 2) BANG PLATE ALL WIRES WITHIN 1 1/4" OF STUD/PLATE FACES-MANY 3) GROUND METAL PANCAKE BOXES 4) NO WATER IN DWV TEST 5) INSTALL DUCT IN LAUDNRY CEILING |
| 10/01/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 09/25/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MECHANICAL DONE EXCEPT LAUNDRY TO POWDER DUCT 2) ELECTRIC N.R. 3) PLUMBING NEED DWV TEST, GAS PRESSURE TEST, WATER PRESSURE HOT AND COLD 4) FRAME OK EXCEPT NAIL OSB AT HIS CLOSET HEADER |
| 08/13/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 08/11/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |