Permit: T02CM05626

Parcel: 110032000

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM05626

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
03/05/2003 FRAMING Approved IVRS - Inspection 0000*
03/04/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) CORRECT OVER NOTCHED BEARING PLATE ON WEST GARAGE WALL 2) FHA STRAP BEARING PLATE AT PLUMBING ON EAST GARAGE WALL-BOTH SIDES AND WEST LIVING WALL 3) FHA STRAP BOTTOM PLATE AT UNDER GROUND ELECTRIC CONDUIT (NAIL ALL FHA HOLES) 4) SHIM PATIO DOOR HEADER 5) PROTECT WIREING FROM FLOOR TRUSS MEETAL GUSSETS 6) SHIM TOP OF WEST STAIR STRINGER 7) REMVOE STAPLES FROM NORTH KITCHEN WALL OSB 8) WATER PRESSURE AND DWV 0K