03/21/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/20/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PLAN SHOWS 2'-3" WALL PANEL AT NORTH WEST CORNER OF GARAGE CORRECT AND RE-CALL 2) LOOSE ROOF PANELS NORTH WEST CORNER 3) NEXT FAILURE WILL INCUR RE-FEE-DO NOT RE-CALL UNTIL CORRECTED
03/17/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) CORRECTIONS NOT MADE
03/14/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROOF OSB NOT NAILED AT NORTH WEST QUADRANT-CHECK ALL 2) FHA STRAP EXTERIOR PLATE CUTS AT PLUMBING 3) WAHT IS ANCHORING TH BOTTOM PLATE AT THE NORTH WEST GARAGE CORNER?