Date Description Inspector Results Comments
03/20/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/17/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) 2 PIECES OF ROOF OSB, ONT THE NORTH ROOF PLANE, ARE NOT STAPED OFF COMPLETELY (SHINERS) 2) DIAGONAL BRACING REQUIRES 2 NAILS AT PLATES 3) FHA STRAP PLATES AT EXTERIOR PLUMBING CUTS