Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/03/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/28/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) HOLDOWNS MISSING REAR 2) INSTALL FHA STRAPS EXTERIOR PLATES PLUMBING/ELECTRIC 3) INSTALL ADDITIONAL STUD REAR 4' SHEAR PANEL 4) PORCH NOT READY 5) PANEL NOT SET (ELECTRIC) |