Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM05582
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/15/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
01/13/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL SHEAR PANELS TO UPPER ROOF DECK 2 TOTAL SMALL ONES IN CLOSETS 2) SHED ROOF ON WEST SIDE SHEATHING RUN WRONG DIRECTION FROM DOUBLE GIRDER UP TO WALL NEED TO TIE BOTH SECTIONS TOGETHER 3) FINISH 1ST-2ND FLOOR TIES 4) NAIL SHED ROOF LEDGER EAST SIDE WITH 8D'S OR LARGER STAPLES TO SHORT 5) FINISH SHEAR NAILING FRONT ALL PANELS TO GO TO TOP CHORD 6) SMALL 2 TOTAL GIRDER HANGERS NEED FULL NAILING 7) WIND BRACE BACK WALL OF DEN 8) NAIL WEST SHED ROOF SHEAR TRANSFER TO ROOF DECK INSTALL ALL BETWEEN SHEAR BLOCK PANELS 798/A8 | |
01/10/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) HOLDOWNS NOT NAILED 2) PROVIDE DOUBLE STUD AT GIRDER |