Permit: T02CM05572

Parcel: 13015001A


Addresses:

4646 E 22ND ST


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T02CM05572

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/05/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*/ OK FOR C OF O.
08/04/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*/ NEED TO SEE ELECTRICAL CONNECTED TO CONDENSOR. YOU CAN HAVE YOUR ELEC. INSPECTOR LOOK OR CALL ME BACK.
08/01/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*/ 1) BLOCK AND CLAMP REFER LINES ON ROOF 2) SEAL AROUND OPENING IN WALL 3) CONNECT LOW VOLTAGE AND HIGH VOLTAGE 4) LEVEL CONDENSOR 5) FINISH CONNECTING AIR HANDLER 6) SECURE REFER LINES AT FAN COIL 7) PROVIDE A 90 DEGREE ELBOW AT SECONDARY CONDENSATE TERMINATION