Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/09/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 01/06/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) NO PRIOR INSPECTION REPORT ON SITE, RESCHEDULE |
| 01/02/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL ABOVE COMPLETED EXCEPT GAS PRESSURE TEST. DISCONNECT ALL GAS APPLIANCES, PLUG FLEX LINES AND PRESSURIZE TOTAL SYSTEM FROM METER IN. MINIMUM 10 PSI. CALL FOR INSPECTION LEAVE SYSTEM UNDER PRESSURE FOR INSPECTION |
| 12/20/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) INADEQUATE EGRESS FROM BEDROOM REQUIRES WINDOW OPEINGIN TO BE A MINIMUM OF 20" WIDE X 24" HIGH 2) DRYER MUST BE ON A FOUR WIRE 30 AMP CIRCUIT WITH A4 PRONG OUTLET 3) KITCHEN SINK NOT PROPERLY VENTED 4) AT LEAST BATTERY OPERATED SMOKE DETECTORS REQUIRED IN EACH BEDROOM AND ROOMS LEADING TO BEDROOM 5) NEED HOLE HOUSE GAS PRESSURE TEST MINIMUM 10 PSI |