Permit: T02CM05543

Parcel: 120022090


Addresses:

4313 S 16TH AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
01/09/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
01/06/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) NO PRIOR INSPECTION REPORT ON SITE, RESCHEDULE
01/02/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ALL ABOVE COMPLETED EXCEPT GAS PRESSURE TEST. DISCONNECT ALL GAS APPLIANCES, PLUG FLEX LINES AND PRESSURIZE TOTAL SYSTEM FROM METER IN. MINIMUM 10 PSI. CALL FOR INSPECTION LEAVE SYSTEM UNDER PRESSURE FOR INSPECTION
12/20/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) INADEQUATE EGRESS FROM BEDROOM REQUIRES WINDOW OPEINGIN TO BE A MINIMUM OF 20" WIDE X 24" HIGH 2) DRYER MUST BE ON A FOUR WIRE 30 AMP CIRCUIT WITH A4 PRONG OUTLET 3) KITCHEN SINK NOT PROPERLY VENTED 4) AT LEAST BATTERY OPERATED SMOKE DETECTORS REQUIRED IN EACH BEDROOM AND ROOMS LEADING TO BEDROOM 5) NEED HOLE HOUSE GAS PRESSURE TEST MINIMUM 10 PSI