Permit: T02CM05501

Parcel: 120072150


Addresses:

4120 S 6TH AV

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/12/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
05/09/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
4120 S. 6TH AV -- SEE UPC SEC. 316.3 ALSO INSTALLATION STANDARDS.
4124 S. 6TH AV. -- CLOSET FLANGES ARE TO BE SECURED TO FLOOR UPC IS 3
316.3.2 -- CLOSET STUBS ARE TO BE EVEN W/THE TOP OF THE RING. INSTALL "DUTCHMEN" WHERE NECESSARY.
03/21/2006 PLUMBING - INTERMEDIATE Partial Approval CORRECT BACK PITCH ON 3"
4124 -- UNIT 110 FLOOR SINKS INSTALLED PER REVISED PLAN OK TO COVER
03/20/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/17/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNIT 115 WATER PIPING OK
UNIT 110 INSTALL FULL SIZE CLEANOUTS ON FS AND 3" CLEANOUT FOR MAIN LINE.
SECURE HOT SIDE WATER PIPING.
11/25/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*WASTE & VENT IN WALLS OK. WATER TEST OK
WATER PIPING REFLECTS CHANGE ON PLANS.
OK TO COVER WALLS.
UNIT115 WATER PIPING NOT COMPLETE.
CALL FOR INSPECTION WHEN READY.
UNIT 110 FLOOR DRAIN NOT INSTALLED.
CALL FOR INSPECTION WHEN READY.
CLOSET FLANGES NOT YET INSTALLED.
CALL FOR INSPECTION WHEN READY.
11/17/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*PROVIDE CLOSET FLANGES ALL UNITS.
WATER TEST WASTE & VENT THRU ROOF
INSTALL WATER PIPING PER PLAN
09/27/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) SOIL WATER TEST IS OK
2) HCS CONNECTION IS OK
3) THIS INSPECTION IS FOR BLDG SEWER FOR ALL UNITS
4) OK TO BACKFILL TRENCH
09/23/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* CITY APPROVED PLAN TO BE ON SITE AT TIME OF INSPECTION.
08/01/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) UNABLE TO LOCATE PLANS AND PERMIT. NO TEST ON INTERMEDIATE PLUMBING ANY WHERE. PLEASE HAVE CITY APPROVED PLAN AND PERMIT ON SITE AT REINSPECTION