Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/09/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 4120 S. 6TH AV -- SEE UPC SEC. 316.3 ALSO INSTALLATION STANDARDS. 4124 S. 6TH AV. -- CLOSET FLANGES ARE TO BE SECURED TO FLOOR UPC IS 3 316.3.2 -- CLOSET STUBS ARE TO BE EVEN W/THE TOP OF THE RING. INSTALL "DUTCHMEN" WHERE NECESSARY. |
|
| 03/21/2006 | PLUMBING - INTERMEDIATE | Partial Approval | CORRECT BACK PITCH ON 3" 4124 -- UNIT 110 FLOOR SINKS INSTALLED PER REVISED PLAN OK TO COVER |
|
| 03/20/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/17/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* UNIT 115 WATER PIPING OK UNIT 110 INSTALL FULL SIZE CLEANOUTS ON FS AND 3" CLEANOUT FOR MAIN LINE. SECURE HOT SIDE WATER PIPING. |
|
| 11/25/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*WASTE & VENT IN WALLS OK. WATER TEST OK WATER PIPING REFLECTS CHANGE ON PLANS. OK TO COVER WALLS. UNIT115 WATER PIPING NOT COMPLETE. CALL FOR INSPECTION WHEN READY. UNIT 110 FLOOR DRAIN NOT INSTALLED. CALL FOR INSPECTION WHEN READY. CLOSET FLANGES NOT YET INSTALLED. CALL FOR INSPECTION WHEN READY. |
|
| 11/17/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*PROVIDE CLOSET FLANGES ALL UNITS. WATER TEST WASTE & VENT THRU ROOF INSTALL WATER PIPING PER PLAN |
|
| 09/27/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) HCS CONNECTION IS OK 3) THIS INSPECTION IS FOR BLDG SEWER FOR ALL UNITS 4) OK TO BACKFILL TRENCH |
|
| 09/23/2005 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CITY APPROVED PLAN TO BE ON SITE AT TIME OF INSPECTION. |
|
| 08/01/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) UNABLE TO LOCATE PLANS AND PERMIT. NO TEST ON INTERMEDIATE PLUMBING ANY WHERE. PLEASE HAVE CITY APPROVED PLAN AND PERMIT ON SITE AT REINSPECTION |