Permit: T02CM05410

Parcel: 10309074B


Addresses:

3871 N COMMERCE DR

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/08/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
05/07/2003 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
05/06/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*
1.) WET VENTING IS LIMITED TO VERTICAL DRAINAGE PIPING MAY NOT HAVE HORIZONTAL DRAINAGE PIPING ON WET VENTED SECTION.
2.) HORIZONTAL X HORZONTAL CHANGE OF DIRECTION TO BE THRU WYE BRANCH OR EQUIVILENT SWEEP.
3.) FIX LEAKS ON ABS.
4.) PLAN SHOW 2-3" VENTS HOWEVER.
5.) IF TOTAL DFU EXCEED 36 DFU YOU WILL BE REQUIRED TO PROVIDE 12.56 AREA OF VENTING.