Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 12/03/2002 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/23/2002 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) ELECTRIC PANEL-DOUBLE TAPPED GROUNDS, HOT UNMARKED NEUTRALS OPEN KNOCKOUTS IN PANEL AND DEAD FRONT HOT WATER HEATER-NEGATIVE PITCH ON TPR DRAIN LINE FURNACE-NEGATIVE PITCH ON CONDENSATE DRAIN, FLUE HEIGHT TOO LOW HOSE BIBS NEEDS BACK FLOW CHECK VALVE ADD GFI OUTLET AT NEW KITCHEN SINK |