Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/13/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) REAR PORCH LEDGER MUST BE SECURED TO RESIST PULL-AWAY (IE... H2.5 OR A35 W/BENT TAB LEDGER TO STUD) |
| 01/07/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) FRONT COLUMN AT ENTRY-COMPLY WITH DETAIL 16/SD-1 POSITIVE CONNECTION REQUIRED TOP AND BOTTOM AT POST BASE AND POST TO BEAM 2) REAR PORCH SHALL COMPLY W/DETAIL 15A/SD1 |