Permit Number - T02CM05377

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/06/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
03/05/2003 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) OUTLET ON REAR GARAGE WALL IS NOT GFI PROTECTED 2) DOWN BATH VENT FLAPPER IS STUCK, LAUNDRY VENT FLAPPER STUCK 3) NEED ELBOW ON TPR DRAIN TERMINATION 4) NEED BACK FLOW VALVE ON NORTH HOSE BIB 5) SEAL UPSTAIRS TOILETS AND OPEN LAUNDRY BOX DRAIN FOR CONDENSATE 6) ADD SPARK SHEILD TO ATTIC HATCH 7) FINISH STOVE GAS INSTALL 8) FINISH GRADE
03/04/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) YARD WATER NOT READY 2) FINAL GRADE NOT READY-OPEN ELECTRIC TRENCH