Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM05377
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/29/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/28/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) BANG PLATE WIRES WHERE NEEDED-MANY 2) PROTECT WIRING FROM FLOOR TRUSS METAL GUSSETTS | |
01/27/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROTECT WIRES AT TRUSS GUSSETTS IN GARAGE CEILING, KITCHEN CEILING 2) FHA STRAP TOP PLATES AT GAS MAIN 3) BANG PLATE WATER AT HOT WATER PLATFORM TOP PLATES AND WIRES AT ENTRY SOUTH WALL AND STAIR NORTHWALL 4) NEED STUD SHOES AT DRAIN PIPES IN LAUDNRY 5) EXTEND MAIN CONDENSATE TO EXTERIOR 6) REPLACE CUT A/C LINE AT KITCHEN CEILING 7) SHIM KITCHEN WINDOW HEADER AND PATIO DOOR HEADER 8) FHA STRAP TOP PLATES AT POWDER ROOM PLUMBING |