Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/17/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 01/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEVERAL PANELS NOT NAILED OFF ON LOWER SOUTH ROOF 2) SHEAR OSB NOT NAILED OFF AT 2ND FLOOR FRONT 3) NON-CABIN TIED TOP PLATES, AT UPPER FRONT LEFT, NEED TO BE STRAPPED 4) PATIO ROOF LEDGER NOT CLIPPED 5) RAKE END TRUSS, AT NORTH END OF ENTRY ROOF, NEEDS STRAP DOWN TO KING 6) NOTE FOR INTER: INSTALL ALTERNATE H.D.'S AT FRONT MIDDLE AND REAR LEFT BLOWOUTS. REAR LEFT CORNER MAY NEED P.T. ENGINEER'S REPAIR |