Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/19/2002 | PLUMBING - INTERMEDIATE | Approved | ||
| 12/10/2002 | PLUMBING - INTERMEDIATE | Denied | 1.) THERE APPEARS TO BE A LEAK @ 4" SPECIALTY COUPLING ABOVE 2" REVENT. 2.) CAN NOT OFF SET TRAP ARM FOR FLOOR DRAIN. 3.) MUST USE DIRECTIONAL FITTING FOR FLAT VENT FOR FLOOR DRAIN. 4.) OK TO DRYWALL PLBG. WALL. |
|
| 12/04/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. | |
| 12/02/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*NO WATER TEST NO PLAN ON JOB SITE CODE VIOLATIONS ON INTERMEDIATE. PLEASE HAVE YOUR PLUMBING ON JOB AT TIME OF NEXT INSP. PROVIDE PHONE # I WILL BE HAPPY TO CALL. DO NOT COVER. |
|
| 11/26/2002 | PLUMBING - INTERMEDIATE | Not ready for Inspection |