Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T02CM05372
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/17/2003 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*80' N/H DRAINAGE TO TIE-INAT EXISTING OK 2" N/H TO KIOSK OK WATER TEST OK TYPE "K" UNDERSLAB OK OK TO COVER NOTE: YOU MAY WISH TO RFI THE ARCHETECT CONCERNING THE USE OF A BFP ABOVE CEILING OVER 5' AFF REQUIRES PLAT FORM. ALSO DEVICE SPEC'D REQUIRES A DRAIN TO WHERE? |
|
04/16/2003 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*1.) A N/H BLAKE TEE IS NOT APPROVED FOR UNDERGROUND NOR IS IT APPROVED ON ITS BACK NOT EVEN FOR A TEST. USE APPROVED DRAINAGE FITTINGS. 2.) WATER TEST DOWN RETEST. |
|
04/15/2003 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION. | |
04/14/2003 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*NOT READY FOR INSPECTION | |
02/04/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*1.) 3' UNDERGROUND FROM KIOSK TO TIE IN AT EXISTING RISER OK 2.) WATER TEST ON RISER TO TEN FEET. 3.) 2 -3/4" TYPE K COPPER LOOPS FROM COLUMN TO KIOSK OK 100# TEST OK 4.) OK TO COVER BOTH AREAS. |