Permit: T02CM05370

Parcel: 106030720

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02CM05370

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2005 PLUMBING - FINAL Approved IVRS - Inspection :* 1) CONTRACTOR TO DI ELECTRICALLY ISOLATE GAL. FROM COPPER AT IRRIGATION 2) PLUMBING FINAL OK. 3) OK FOR C OF O PENDING ANY OTHER INSPECTIONS
04/01/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) YARD WATER NOT INSTALLED PER PLAN. 2) CONTRACTOR NEEDS TO REVEAL ALL FITTINGS FOR INSPECTOR. 3) COPPER DIRECTLY EMBEDDED IN CONCRETE.
03/28/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) PROVIDE DOCUMENTATION FOR APPROVAL OR YARDWATER, OR EXPOSE PIPING. 2) REVISED PLAN ON SITE. ROUGH-SOIL APPR.
02/03/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) NO BACKWATER REQUIRED FINAL NOT READY. CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS BEFORE CALLING FINAL.