Permit: T02CM05337

Parcel: 12710017D


Addresses:

899 N WILMOT RD #C1


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T02CM05337

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
02/18/2003 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
02/12/2003 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) SUPPORT CONDUIT IN TRUSSES AND WALLS AS PER CODE. INSULATION HINDIRING VIEW OF CONDUIT RUNS AND DRYWALL STACKED AGAINST WALLS 2) SECURE CONDUIT SUPPORTS 3) PROTECT PVC CONDUIT AT BASE BOARD 4) FILL UNUSED OPENINGS IN JUNCTION BOXES 5) PLASTER RINGS NEED TO BE INSTALLED
01/27/2003 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*PLEASE ADD UNDERGROUND ELECTRIC TO PERMIT.