Permit: T02CM05330

Parcel: 141172100


Addresses:

10382 E ROYWOOD WY

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/31/2003 FRAMING Approved IVRS - Inspection 0000*
01/30/2003 FRAMING Not ready for Inspection 1) BOTH TUB SHOES LEAKING 2) BANG PLATES AT GARAGE EAST WALL PLUMBING AND REAR WALL ELECTRIC TOP PLATES 3) SHEAR BLOCKS, AT NOOK 4) DETECTIVE GAS GAUGE
01/29/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NEED 2 X 4 CONTINOUS BRACES ON GABLE END DIAGONAL BRACES PER DT1/6 2) CHECK ALL A8'S. STUCCO MESH INSTALLATION NOT COMPLETED 3) 03035 NO WATER TEST ON DWV PIPING 4) NEXT INSPECTION CHECK AROUND WIRING AND PEX PIPING FOR STUCCO MESH STAPLES PENETRATION