Permit: T02CM05320

Parcel: 14029050A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/03/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
03/21/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) MUST PROVIDE A BACKFLOW PREVENTER FOR EACH DISPENSING MACHINE THAT REQUIRES POTABLE WATER SUPPLY. TESTED CERTIFIED BY TIME OF INSPECTION SEE SECTION: 603.0 94 UPC.
2.) MUST USE DIRECTIONAL FITTING FOR CONTINUOUS WASTE SEE SECTION: 405.4 94 UPC.
3.) MUST PROVIDE DESANKOS FOR 17 GAS TRA ARM
4.) CAN ONLY HAVE (1) SLIP JOINT ON TRAP ARM SER SECTION: 1003.2. 94 UPC.
5.) MUST HAVE MIN 1" AIR GAP ON INDIRECT WASTE FOR PREP SINK.
6.) SUPPLY FOR BACKFLOW PREVENTERS MUST BE THE SMAE SIZE AS INLET SEE SECTION: 610.2 94 UPC.
7.) WILL REQUIRE A REVISED AND APPROVED DRAWING ON WATER DISTRIBUTION SERVING EXTRAS BACKFLOW PREVENTERS PRIOR TO FINAL INSPECTION.