Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T02CM05315
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2003 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
| 02/25/2003 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection 0999* ALL WIRES IN BOXES MUST BE MADE UP. THE USE OF SINGLE CONDUCTORS TO BUNDLE CABLER TOGETHER IS NOT CORRECT. USE TY-RAPS OR OTHER BRAND OF CABLE TIE. FINISH WIRING AT FIREPLACE AREA. |
|
| 02/13/2003 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*FURN. PER PLAN WILL REQUIRE A 40 AMP BREAKER. RANGE HAS 50 AMP BREAKER TO AND #8-3 ROMEX IS RATED FOR 40 AMP NEC 336-26. STORAGE ROOM RECEPT, MUST BE UP 18" FROM GARAGE FLOOR LEVEL. AT LOWER AREA. A BOX IS REQUIRED FOR THE WALL BATH FIXTURE (UNLESS LISTING IS OBTAINED.) ADD WIRE PROTECTION PLATE AT AREAS IE. ABOVE BATHROOM. OK TO INSULATE. SUBJECT TO OTHER INSPECTION. FURTURE UNDERGROUND CONDUCT TO PATIO APPROVED. |