Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM05263
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/19/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NEED SHEAR CONTINOUS TO DOUBLE BLOCKS, DROP CEILING SD NOT SHOWN ON PLAN 2) SHEARWALL ONE AT ENTRY NEEDS TO TIE TO ROOF ALSO AT EAST BEDROOMS FRONT AND BACK 3) GALBE BRAVCE DETAIL AT 6' ON CENTER TIE THREE TRUSSES WITH BRACE TIE #25 IN SHEAR 4) MECH CUT DOUBLE TOP PLATE HEADER OFF | |
12/18/2002 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) NEED CROSS BRACE AT MIDSPAN TRUSSES 2) ADD 2 X 4 BRACES 6' ON CENTER GABLE ENDS | |
12/17/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE TRUSS CALC'S 2) ROOF INCOMPLETE 3) HD'S NOT NAILED 4) SHEAR NOT NAILED |