Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM05199

Parcel: 141301540

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM05199

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/07/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) VERTICAL SUPPORT (EAST GARAGE WALL) BUILT UP 2 X 4 UNDER GIRDER FROM 2ND FLOOR ADD 2 STUDS 2) HT OF WALKING DECK NOT CORRECT, ADDING WROUGHT IRON ON TOP NOT UP TO CODE 3) TIMER STRAND HEADER REAR SLIDER, 2ND FLOOR 2-2 X 10 -3 1/2" X 7 1/4" 4) T-2 AND T2A TRUSSES GET LATERAL BRACING SEE TRUSS DRAWINGS 5) NAIL SHEAR PANELS TO ROOF WITH 8D'S AT 4/SD4 6" ON CENTER 6) NAIL ALL BLOCKING PANELS TO FLOOR TOP PLATES PER 6/SD2 7) WALKING DECK LEDGER DETAIL 10/SD2