Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 11/20/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 11/19/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) SET GRADE PINS (12" MINIMUM FTG. DEPTH) 2) WRAP ABS IN CONTACT WITH CONCRETE 3) PORCH POST FTGS TO HAVE 2-#4'S EACH WAY 4) #5'S AT ENDS OF DOORS, WINDOWS, JAMS VERTICAL REQUIRED 5) 2-#5'S WHERE NEW MEETS, OLD MASONRY 6) 2 #4'S IN TOP OF STEM 7) STOPPED INSPECTION 8) CORRECT ALL AND RECALL 9) EXPOXIED REBAR 8" EMBEDMENT EXTENDING NEW WALL PARAPET 32" ON CENTER SPACING (SPECIAL INSPECTION REPORT REQUIRED) 10) MUST CARRY #5 VERTICALS FULL HEIGHT 11) #3 TIES HORIZONTAL 16" SPACING AT CORNERS AND ENDS (MASONRY) |