Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/12/2003 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000*/1) SOIL WATER TEST IS OK. 2) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK. 3)OK TO BACKFILL TRENCH. |
| 09/11/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
1) MUST PAY RE-INSPECTION FEE BEFORE THE NEXT INSPECTION. |
| 09/10/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) CHECK ITEMS ABOVE AS REQUESTED AND MAKE ALL CORRECTIONS PRIOR TO CALLING FOR INSPECTION |
| 09/05/2003 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST PROVIDE 10' HEAD OF WATER TEST ON SYSTEM 2) CAN NOT HAVE FLAT FACED BUSHINGS IN A HORIZONTAL POSITION 311.5 94 UPC INTERPETATIONS 3) MUST USE A DIRECTIONAL FITTINGS WHEN EXTENDING CLEANOUT 4) CAN NOT USE FERNCO COUPLINGS WITHIN THE STRUCTURE 5) CAN NOT USE JIM CAPS AS PERM. CAPS. MUST USE APPROVED PERM CAPS |